WTB and MVB Analysers

Analysers of the WTB and MVB bus are passive bus elements, which monitor the traffic on the bus and pass it to the Ethernet bus in UDP frames. A PC is attached to the Ethernet bus with a program for receiving and evaluating the UDP frames.

The analyser only monitors the bus – it is “invisible” for other devices. All WTB or MVB frames on the bus are monitored. A timestamp is added to each frame and then passed to the Ethernet bus within the UDP frame. More MVB or WTB frames can be stored into a single UDP frame in order to optimize the utilization of the Ethernet bus.

The open source program Wireshark is used on the PC for which an add-in is supplied. Wireshark is generally a widely-used software that has become the standard for network protocols analysis.

It is possible to use this program with a supplied add-in to view the individual frames of TCN communication and also to get some statistical information from the WTB or MVB layer, e.g. the minimum and maximum gap between master and slave frame. It is also possible to analyse protocols from higher layers (TCN PD and TCN MD protocol). Moreover, when analysing the TCN MD protocol, we can view the whole TCN messages; when UIC E-Telegrams is being transmitted, its header and even the individual items for standard E-Telegrams is viewable. The user is allowed to modify or extend the supplied add-in arbitrarily, e.g. to add an analysis of its own application protocol.

WTB Analysers

WTB interface

1 × (doubled line)

   Galvanic separation

EMD

   Connectors

4× D-sub DE-9 connector
according to IEC 4-61375-1 ed.2

   Communication rate

1 Mbps ± 0.01 %

Ethernet

1 ×

   Communication rate

100 Mbps

   Galvanic separation

yes

   Connector

RJ45

Power supply

24 V DC (-30 % to +25 %)

Protection rate

IP30

Mounting

into subrack

Operating temperature

-40 °C to 70 °C

Weight

1,55 kg

Dimensions (w × h × d)

(142 × 129 × 185) mm

Standards

EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2, IEC61375-1, IEC61375-2, IEC 61375-3-4, UIC CODE 556, MIL HDBK217F2

 

MVB Analysers

MVB interface

1 × (2 redundant lines), Class 1

   Interface type

EMD / ESD

   Connectors

2× D-Sub DE-9 (concatenation)

   Communication rate

1.5 Mbps ± 0.01 %

Ethernet

1 ×

   Communication rate

10 / 100 Mbps

   Galvanic separation

yes

   Connector

RJ45

Power supply

24 V DC (-30 % to +25 %)

Protection rate

IP20

Mounting

2 × ø 6 mm hole

Operating temperature

-40 °C to 70 °C

Weight

0,90 kg

Dimensions (w × h × d)

(50 × 228 × 113) mm

Standards

EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2, IEC 61375-3-1

 

 