I/O Units with TRDP
RRT2-xxx are remote I/O units designed and optimized to control rolling stock. Units communicate with other parts of TCMS through TRDP protocol. The units meet the requirements of EN 50155 (Electronic equipment used on rolling stock) class TX.
CAN interface | 1 × |
Communication rate | 250 / 500 / 1000 kbps |
Communication protocol | CANopen DS 401 |
Power supply | 24 V / 48 V DC (-30 % to +25 %) |
Protection rate | IP30 |
Operating temperature | -40 °C to 70 °C |
Mounting | 35 mm DIN rail |
Weight | 1,25 g |
Dimensions (w × h × d) | (170 × 100 × 108) mm |
Standards | EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2 |
Types available:
input / output | DI | DO | RDO | AI | AO | Vcc |
RRC-I/001 | 32 | - | - | - | - | 24 V DC |
RRC-I/005 | 32 | - | - | - | - | 48 V DC |
RRC-IO/001 | 16 | 8 | - | - | - | 24 V DC |
RRC-AIO/001 | 12 | 6 | - | 4 (4 mA to 20 mA) | - | 24 V DC |
RRC-AIO/201 | 12 | 6 | - | 4 (0 V to 15 V) | - | 24 V DC |
RRC-IOR/001 | 12 | 7 | 2 | - | - | 24 V DC |
RRC-O/001 | - | 16 | - | - | - | 24 V DC |
RRC-O/005 | - | 16 | - | - | - | 48 V DC |
RRC-ION/001 | 12 | 8 | - | - | 4 (4 mA to 20 mA) | 24 V DC |