Converters
Converters linking Ethernet with CAN, RS485 and digital I/O. Their robust, vibration-proof design uses M12 Ethernet connections, covers an operating temperature range of -40 °C to 70 °C and complies with EN 50155.
Models and parameters
| Parameter | RRC-PP3 (Ethernet / CAN / RS485) | RRC-PP4 (Ethernet / CAN / RS485) | RRC-PP5 (Ethernet / CAN / RS485) |
|---|---|---|---|
| Ethernet | 1× 100 Mbps Full Duplex, M12, D-coded / IO | 1× 100 Mbps Full Duplex, M12, D-coded / IO | 1× 100 Mbps Full Duplex, M12, D-coded / IO |
| RS485 interface | 2× with galvanic isolation, D-Sub DE-9 | 2× with galvanic isolation, D-Sub DE-9 | 2× with galvanic isolation, D-Sub DE-9 |
| Power supply | 16.8 V to 33.6 V DC | 16.8 V to 33.6 V DC | 16.8 V to 50.4 V DC |
| Power consumption | Max. 0.1 A at 24 V DC | Max. 0.15 A at 24 V DC | Max. 0.15 A at 24 V DC |
| Cover protection rate | IP20 | IP20 | IP20 |
| Operating temperature range | -40 °C to 70 °C | -40 °C to 70 °C | -40 °C to 70 °C |
| Mounting | 2 × ø 6 mm hole | 2 × ø 6 mm hole | 4 × ø 6 mm hole |
| Weight | 0.7 kg | 1 kg | 1.3 kg |
| Application software | Project customized | Project customized | Project customized |
| CAN | – | 1× (concatenation) | 2× (concatenation) |
| Digital I/O | – | – | 16 × DI, 2 × DO, 24 V DC |
Standards
- EN 50155
- EN 50121-3-2
- EN 45545-2