The remote I/O units are represented by the RRC-xxx product line. These units are designed and optimized for railway vehicle control and communicate with the central control system using the CANopen DS 401 protocol. The units comply with the requirements of ČSN EN 50155 (electronic equipment for railway vehicles), class TX.

The CAN connectors are daisy-chained (simplified cabling). For setting the communication speed and unit address, a plug-in module RRC-KM is used, which can be part of the cabling (ensuring the so-called geographical node configuration). This solution minimizes configuration errors during possible servicing and replacement. Connection connectors for signals are WAGO type X-COM.

  • Robust design
  • Support for CANopen DS 401 protocol
  • Extended operating temperature range -40 °C to 70 °C
  • Designed for extreme climatic conditions
  • Construction according to EN 50155

    CAN rozhraní

   Komunikační rychlost

250 / 500 / 1000 kb/s

   Komunikační protokol

CANopen DS 401

   Napájení

24 V / 48 V ss. (-30 % až +25 %)

   Krytí

IP30

   Pracovní teplota

-40 °C až 70 °C

   Montáž

35 mm DIN lišta

   Hmotnost

1,25 kg

   Rozměry (š × v × h)

(170 × 100 × 108) mm

   Normy

EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2

 

Dostupné typy:

vstupy / výstupyDIDORDOAIAOVcc
   RRC-I/0013224 V ss.
   RRC-I/0053248 V ss.
   RRC-IO/00116824 V ss.
   RRC-AIO/0011264 (4 mA až 20 mA)24 V ss.
   RRC-AIO/2011264 (0 V až 15 V)24 V ss.
   RRC-IOR/001127224 V ss.
   RRC-O/0011624 V ss.
   RRC-O/0051648 V ss.
   RRC-ION/0011284 (4 mA až 20 mA)24 V ss.
   RRC2-IO/00116824 V ss.
   RRC2-AIO/001168424 V ss.
   RRC2-I/0013224 V ss.