Subrack vehicle control unit with communication and I/O card mainly for TCMS applications.
Rugged and temperature-durable control system for rolling stock applications.
Rugged and temperature-durable control system for rolling stock applications.
- CANopen DS 401 communication protocol
- MVB interface EMD, ESD (double line attachment)
- 10 / 100 Mbps Ethernet (M12 connector attachment)
- WTB interface (UIC 556 certified)
- Standby redundancy within subtrack (CPU, power, gateway unit, I/O units)
- Wide operating temperature range -40 °C to 70 °C
- Wide range of power supply voltages 24 V DC to 110 V DC
- EN 50155 compliant
POWER SUPPLY UNITS
Type | RV-PW04/100x |
---|---|
Max power | 40W |
Power supply | 24 V / 48 V / 72 V / 110 V DC |
RV-PW04/100x
Max power:
40W
Power supply:
24 V / 48 V / 72 V / 110 V DC
VEHICLE CONTROL UNITS
Type | RV-CPMC/1x01 |
---|---|
MVB Class | class 1: DS + PD class 2: DS + PD + MD class 3: DS + PD + BA class 4: DS + PD + MD + BA |
CAN | 1 - 6 |
CANopen | Master |
Ethernet | 10 / 100 Mbps (M12) |
RV-CPMC/1x01
MVB Class:
class 1: DS + PD
class 2: DS + PD + MD
class 3: DS + PD + BA
class 4: DS + PD + MD + BA
class 2: DS + PD + MD
class 3: DS + PD + BA
class 4: DS + PD + MD + BA
CAN:
1 - 6
CANopen:
Master
Ethernet:
10 / 100 Mbps (M12)
SUBRACK 19” SYSTEM CENTRAL CONTROL UNIT
Type | RV-CPTRDP/1100 |
---|---|
Protocol | TRDP TCNOpen 1.3.3.0 |
Ethernet | Ethernet connector M12 |
Interfaces | CAN interface, connector concatenation Internal communication interface RAVA |
Power supply | 24 V DC |
Operating temperature range | -40 °C to 70 °C |
Dimension | 8HP x 3V |
Mounting | 19" subrack RV-RC0xx |
Standards | EN 50155, EN 50121-3-2, EN 45545-2 EN 60068-2-1, EN 60068-2-2 |
RV-CPTRDP/1100
Protocol:
TRDP TCNOpen 1.3.3.0
Ethernet:
Ethernet connector M12
Interfaces:
CAN interface, connector concatenation
Internal communication interface RAVA
Internal communication interface RAVA
Power supply:
24 V DC
Operating temperature range:
-40 °C to 70 °C
Dimension:
8HP x 3V
Mounting:
19" subrack RV-RC0xx
Standards
Standards:
EN 50155, EN 50121-3-2, EN 45545-2
EN 60068-2-1, EN 60068-2-2
EN 60068-2-1, EN 60068-2-2
Type | RV-RC010 | RV-RC015 | RV-RC021 |
---|---|---|---|
Number of slots | 10 | 15 | 21 |
RV-RC010
Number of slots:
10
RV-RC015
Number of slots:
15
RV-RC021
Number of slots:
21
SUBRACK UNITS
Units specific parameters | ||||
---|---|---|---|---|
Type | DI | DO | AI | AO |
RV-I/0111 | 32 (24 V) | |||
RV-O/0211 | 24 (24 V / 4 A, HSS) | |||
RV-F/0211 | 24 (24 V / 4 A, HSS) | |||
RV-A/1110 | 12 (0 mA to 30 mA) | |||
Standards | EN 50155, EN 50121-3-2, EN 45545-2 |
RV-I/0111
DI:
32 (24 V)
DO:
-
AI:
-
AO:
-
RV-O/0211
DI:
-
DO:
24 (24 V / 4 A, HSS)
AI:
-
AO:
-
RV-F/0211
DI:
-
DO:
24 (24 V / 4 A, HSS)
AI:
-
AO:
-
RV-A/1110
DI:
-
DO:
-
AI:
12 (0 mA to 30 mA)
AO:
-
Standards
Standards:
EN 50155, EN 50121-3-2, EN 45545-2